Publication: Dynamic measuring of force-displacement-characteristics of shockmounts
cris.customurl | 19052 | |
cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.department | Mechatronik | |
cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtual.departmentbrowse | Mechatronik | |
cris.virtual.departmentbrowse | Mechatronik | |
cris.virtualsource.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
cris.virtualsource.department | 78c40bb4-440b-4e70-a918-f0d50570078e | |
cris.virtualsource.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
dc.contributor.author | Heinemann, Bernhard | |
dc.contributor.author | Dreesen, Jan | |
dc.contributor.author | Sachau, Delf | |
dc.date.issued | 2023 | |
dc.description | This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (https://creativecommons.org/licenses/by-nc-nd/4.0/). | |
dc.description.abstract | Shockmounts are widely used to isolate sensitive equipment from vibrations and mechanical shock. Despite the highly dynamic nature of shock events, the force-displacement-characteristics of shockmounts which are provided by manufacturers are gained by static measurements. Therefore, this paper presents a dynamic mechanical model of a setup for dynamic measurements of force-displacement-characteristics. The model bases on acceleration measurement of an inert loading mass, which displaces the shockmount, when the arrangement gets excited by means of a shock test machine. The influence of the shockmount’s mass in measuring setup is considered as well as special needs for handling measurements under shear or roll loading. A method for allocating the measured force data on the displacement axis is developed. An equivalent of a hysteresis-loop in a decaying force-displacement-diagram is proposed. Based on exemplary measurements, error calculation and statistical analysis show the qualification of the proposed method for attaining dynamic FDC. | |
dc.description.version | VoR | |
dc.identifier.articlenumber | e16743 | |
dc.identifier.doi | 10.1016/j.heliyon.2023.e16743 | |
dc.identifier.issn | 2405-8440 | |
dc.identifier.uri | https://openhsu.ub.hsu-hh.de/handle/10.24405/19052 | |
dc.language.iso | en | |
dc.publisher | Elsevier | |
dc.relation.journal | Heliyon | |
dc.relation.orgunit | Mechatronik | |
dc.rights.accessRights | metadata only access | |
dc.subject | Shock isolator | |
dc.subject | Wire rope shockmount | |
dc.subject | Elastomer shockmount | |
dc.subject | Dynamic force-displacement-characteristics | |
dc.subject | Force surface | |
dc.subject | Naval | |
dc.title | Dynamic measuring of force-displacement-characteristics of shockmounts | |
dc.type | Forschungsartikel | |
dcterms.bibliographicCitation.originalpublisherplace | London [u.a.] | |
dspace.entity.type | Publication | |
hsu.contributor.identifier | Heinemann, Bernhard;1757032924;gnd/1232733342 | |
hsu.contributor.identifier | Sachau, Delf;549545255;gnd/120120852 | |
hsu.lom.import | true | |
hsu.opac.importErsterfassung | 0705:05-06-23 | |
hsu.peerReviewed | ✅ | |
hsu.uniBibliography | ✅ | |
oaire.citation.issue | 6 | |
oaire.citation.volume | 9 |